GB
15
Burner and nozzle specifications
Table 1 Liquid Gas Natural Gas
Burner Diameter Thermal Thermal By-pass Nozzle Flow* Thermal Nozzle Flow*
power power 1/100 1/100 (g/h) power 1/100 (l/h)
kW kW kW
(p.c.s.*) (p.c.s.*) (p.c.s.*)
(mm) Reduced Nominal (mm) (mm) *** ** Nominal (mm)
Supply pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
Reduced Fast (RR)
Semi Fast (S)
Auxiliary (A)
Triple Crown (TC)
100
75
55
130
0.70
0.40
0.40
1.50
2.60
1.90
1.00
3.30
39
28
28
61
80
70
50
91
189
138
73
240
186
136
71
236
2.60
1.90
1.00
3.60
110 (Y)
106
79
145 (H1)
248
181
95
343
* At 15°C and 1013 mbar - dry gas
** Propane P.C.S. = 50.37 MJ/Kg
*** Butane P.C.S. = 49.47 MJ/Kg
Natural P.C.S. = 37.78 MJ/m
3
RR
TC
S
S
A
PFS750T/HA
! The hob can only be installed above built-in ovens with a cooling ventilation system.