Check that the hose fits firmly into place at the two ends and fix it with clamps complying with current standards. If any of
the above recommendations can not be followed, flexible metal pipes should be used. If the cooker is installed in compliance
with the requirements for class 2, subclass 1, it is highly recommended that the gas connection be made with a flexible
metal pipe in compliance with current safety standards.
Connecting a FConnecting a F
Connecting a FConnecting a F
Connecting a F
lele
lele
le
xibxib
xibxib
xib
lele
lele
le
,,
,,
,
J J
J J
J
ointlessointless
ointlessointless
ointless
,,
,,
,
Stainless Steel Pipe to a Stainless Steel Pipe to a
Stainless Steel Pipe to a Stainless Steel Pipe to a
Stainless Steel Pipe to a
TT
TT
T
hrhr
hrhr
hr
eaded eaded
eaded eaded
eaded
AttacAttac
AttacAttac
Attac
hmenthment
hmenthment
hment
Remove the hose holder fitted on the appliance. The gas supply pipe fitting is a threaded 1/2 gas cylindrical male attachment.
Use only pipes and seals that comply with current National Regulations. The full length of the pipe when installed must not
exceed 2000 mm. After the connection has been made, make sure that the flexible metal pipe does not come into contact
with moveable parts and that it is not crushed.
ChecChec
ChecChec
Chec
king the Sealking the Seal
king the Sealking the Seal
king the Seal
Important: Once the installation has been completed, check to make sure that the seals on all the connections are tight,
using a soapy solution (never a flame).
Connecting the PConnecting the P
Connecting the PConnecting the P
Connecting the P
oo
oo
o
ww
ww
w
er Suppler Suppl
er Suppler Suppl
er Suppl
y Cory Cor
y Cory Cor
y Cor
d to the Mainsd to the Mains
d to the Mainsd to the Mains
d to the Mains
Install a normalised plug corresponding to the load indicated on the data plate. When connecting the cable directly to the
mains, install an omnipolar circuit-breaker with a minimum contact opening of 3 mm between the appliance and the mains.
The omnipolar circuit breaker should be sized according to the load and should comply with current regulations (the earth
wire should not be interrupted by the circuit breaker). The supply cable should be positioned so that it does not reach a
temperature of more than 50°C with respect to the room temperature, along its length. Before making the connection,
check that:
• The limiter valve and the home system can support the appliance load (see data plate);
• The mains are properly earthed in compliance with current safety standards and regulations;
• There is easy access to the socket and omnipolar circuit breaker, once the hob has been installed.
N.B.: Never use reducers, adaptors or shunts since they can cause heating or burning.
ConCon
ConCon
Con
vv
vv
v
erer
erer
er
ting the Cookting the Cook
ting the Cookting the Cook
ting the Cook
er to Difer to Dif
er to Difer to Dif
er to Dif
ff
ff
f
erer
erer
er
ent ent
ent ent
ent
TT
TT
T
ypes ofypes of
ypes ofypes of
ypes of
Gas Gas
Gas Gas
Gas
In order to convert the cooker for use with a type of gas different than the one for which it was factory set (indicated on the
label attached to the lid), the following steps must be taken:
a) Replace the hose holder mounted on the appliance with that supplied in the bag of “cooker accessories.”
Important: The hose holder for liquid gas is marked 8, the hose holder for methane. In any case, always use a new
sealing gasket.
b) Replace the burner nozzles on the hob:
• Remove the grids and slide the burners from their housings;
• Unscrew the nozzles using a 7 mm socket spanner, and replace them with nozzles for the new type of gas (see
table 1 “Burner and Nozzle Characteristics”).
• Replace all the components by repeating the steps in reverse order.
c) Minimum regulation of the hob burners:
• Turn the tap to minimum;
• Remove the knob and adjust the regulation screw, which is positioned in or next to the tap pin, until the flame is small
but steady.
N.B.: In the case of liquid gas, the regulation screw must be screwed in all the way.
• Check that the flame does not go out when you turn the tap quickly from high to low.
d) Regulating the primary air of the burners: The primary air of the burners does not need to be regulated.
ImporImpor
ImporImpor
Impor
tanttant
tanttant
tant
On completion of this operation, replace the old rating sticker with one indicating the new type of gas used. This sticker is
available from our Service Centres.
NoteNote
NoteNote
Note
Should the pressure of the gas used be different (or vary) from the recommended pressure, it is necessary to fit a suitable