GB
17
Burner and nozzle specifications
Table 1 Liquid gas Natural gas
BURNER
Diameter
(mm)
Thermal power
kW (H.s.*)
By-pass
1/100
(mm)
Injector
1/100
(mm)
Flow *
g/h
Injector
1/100
(mm)
Flow*
l/h
Nomin. Reduc. G30 G31 G20
D.
Triple Ring
130 3.25 1.3 57 91 236 232 124 309
C.
Rapid
100 3.00 0.7 40 86 218 214 116 286
B.
Semi-rapid
75 1.65 0.4 30 64 120 118 96 157
A.
Auxiliary
55 1.00 0.4 30 50 73 71 71 95
I.
Double flame DC DR (internal)
30 0.90 0.4 30 44 65 64 70 86
I.
Double Flame DC DR (external)
130 4.10 1.3 57 70 298 293 110 390
Supply pressure
Nominal
Minimum
Maximum
28-30
20
35
37
25
45
20
17
25
* At 15°C and 1013 mbar - dry gas
** Propane P.C.S. = 50.37 MJ/Kg
*** Butane P.C.S. = 49.47 MJ/Kg
Natural P.C.S. = 37.78 MJ/m3
! The hob can only be installed above built-in ovens with a cooling ventilation system.
DATA PLATE
Electrical
connections
voltage of 220-240V ~ 50/60Hz
(see data plate )
This appliance conforms to the
following European Economic
Community directives:
-73/23/EEC dated 19/02/73 (Low
Voltage) and subsequent
amendments
- 89/336/EEC dated 03/05/89
(Electromagnetic Compatibility) and
subsequent amendments
- 93/68/EEC dated 22/07/93 and
subsequent amendments.
- 90/336/EEC dated 29/06/90 (Gas)
and subsequent amendments.
- 2002/96/EC
ICA
C
B
D
A
C
A
PPF 20 65 - PPF 20 65 BNV - B 20 65/CS
PP 30TC 120 - PPF 30TC 120 - PPF 30TC 120 BNV -
B 30TC 120/CS
PPF 20DC 120 - PPF 20DC 120 BNV - B 20DC 120/CS
B
D
A
C
B 30TC 138/CS BNV
Comentarios a estos manuales