Having obtained the low flame setting required
and with the burner lit, abruptly change the
position of the knob several times from minimum
to maximum and vice versa and check that the
flame does not go out.
In appliances fitted with the safety device
(thermocouple), should the device fail to work with the
burners set to the low flame setting, increase the low
flame setting of the same on the adjusting screw.
Once the adjustment has been made, remount the
seals on the by-passes using sealing wax or similar.
Electrical connection
THE APPLIANCE MUST BE EARTHED
The appliance is designed to work with alternating
current at the supply voltage and frequency indicated
on the rating plate (situated on the rear part of the
appliance and on the last page of the instruction
booklet) or at the end of the instruction booklet. Make
sure that the local supply voltage corresponds to the
voltage indicated on the rating plate.
To connect directly to the mains supply, a double-
pole switch with a contact separation of at least 3
mm suitable for the load and complying with current
standards and regulations, must be fitted between the
appliance and the mains supply outlet. The yellow-
green earth wire must not be interrupted by the switch.
The supply cable must be in such a position that no
part of it can reach a temperature of 50 °C above
room temperature. Do not use adapters or shunts as
they could cause heating or burning. Before
connecting to the power supply, make sure that:
the limiter valve and the domestic system can
withstand the load from the appliance (see rating
plate);
the supply system is efficiently earthed according to
standards and laws in force;
the socket or double-pole switch are easily
accessible when the appliance is installed.
FAILURE TO OBSERVE THE ACCIDENT-PREVENTION
REGULATIONS RELIEVES THE MANUFACTURER OF
ALL LIABILITY.
Important: the wires in the mains lead are coloured
in accordance with the following code:
Green & Yellow - Earth
Blue - Neutral
Brown - Live
As the colours of the wires in the mains lead may
not correspond with the coloured markings
identifying the terminals in your plug, proceed as
follows:
Connect the Green & Yellow wire to terminal marked
E or
or coloured Green or Green & Yellow.
Connect the Brown wire to the terminal marked L or
coloured Red.
Connect the Blue wire to the terminal marked N or
coloured Black.
Replacing the cable
Use a rubber cable of the type H05VV-F with a
suitable cross section 3 x 1.5 mm².
The yellow-green earth wire must be 2-3 cm longer
than the other wires.
Disposal
When disposing of packaging material: observe
local legislation so that the packaging may be
reused.
The European Directive 2002/96/EC relating to
Waste Electrical and Electronic Equipment (WEEE)
states that household appliances should not be
disposed of using the normal solid urban waste
cycle. Exhausted appliances should be collected
separately in order to optimise the cost of re-using
and recycling the materials inside the machine,
while preventing potential damage to the
atmosphere and to public health. The crossed-out
dustbin is marked on all products to remind the
owner of their obligations regarding separated
waste collection.
For further information relating to the correct
disposal of exhausted household appliances,
owners may contact the public service provided or
their local dealer.