Table of burner and nozzle specifications
TABLE OF CHARACTERISTSICS
Dimensions
width 43,5 cm
height 32 cm
depth 40 cm
Volume
56 l
Useful
measurements
relating to the oven
compartment
width 46 cm
height 8,5 cm
depth 44 cm
Burners
may be adapted for use with any type
of gas shown on the data plate.
Voltage and
frequency
see data plate
ENERGY LABEL
Directive 2002/40/EC on the label of
electric ovens.
Standard EN 50304
Energy consumption for Natural
convection – heating mode:
Convection;
Declared energy consumption for
Forced convection Class – heating
mode: Baking
This appliance conforms to the
following European Economic
Community directives: 2006/95/EC
dated 12/12/06 (Low Voltage) and
subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments -
2004/142/EC dated 30/11/09 (Gas)
and subsequent amendments -
93/68/EEC dated 22/07/93 and
subsequent amendments.
2002/96/EC
1275/2008 (Stand-by/ Off mode)
TC
A
S
R
K6T52.S A /I
* At 15°C and 1013 mbar- dry gas
** Propane P.C.S. = 50,37 MJ/Kg
*** Butane P.C.S. = 49,47 MJ/Kg
Natural P.C.S. = 37,78 MJ/m
3
Table 1 Liquid Gas Natural Gas
Burner Diameter
(mm)
ThermalPoer
kW(p.c.s.*)
By-Pass
1/100
Nozzle
1/100
lo*
g/h
Nozzle
1/100
lo*
l/h
Nominal Reduced (mm) (mm) *** ** (mm)
ast
(arge)(R)
100 3,00 0,7 41 86 218 214 116 286
Semiast
(Medium)(S)
75 1,90 0,4 30 70 138 136 106 181
Auiliary
(Small)(A)
55 1,00 0,4 30 50 73 71 79 95
TripleRing
(TC)
130 3.25 1.5 63 91 236 232 133 309
Supply
Pressures
Nominal(mbar)
Minimum(mbar)
Maimum(mbar)
28-30
20
35
37
25
45
20
17
25