Burner and nozzle specifications
Table 1 Liquid gas Natural gas
Burner Diameter
(mm)
Thermal power
kW (p.c.s.*)
By-pass
1/100
(mm)
Nozzle
1/100
Flow*
g/h
Nozzler
1/100
Flow*
l/h
Nom. Red. (1) (mm) *** ** (mm)
Fast
(Large) (R)
100 3.00 0.7 41 39 86 218 214 116 286
Reduced Fast
(RR)
100 2.60 0.7 41 39 80 189 186 110 248
Semi Fast
(Medium) (S)
75 1.65 0.4 30 28 64 120 118 96 157
Auxiliary
(Small) (A)
55 1.00 0.4 30 28 50 73 71 71 95
Triple Crown (TC) 130 3.25 1.3 60 57 91 236 232 133 309
Semi-FishBurner
(SP)
- 1.50 0.7 41 39 60 109 107 88 143
Supply pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
* At 15°C and 1013 mbar - dry gas *** Butane P.C.S. = 49.47 MJ/Kg
** Propane P.C.S. = 50.37 MJ/Kg Natural P.C.S. = 37.78 MJ/m
3
Table1 (For Hungary) G 20 G 25.1 G 30
Burner
Thermal power
kW
Nozzle
1/100 (mm)
Thermal power
kW
Nozzle
1/100 (mm)
Thermal power
kW
Nozzle
1/100 (mm)
Reduced Fast (RR) 2,45 110 1,90 110 2,30 80
Semi Fast (Medium) (S) 1,60 96 1,25 96 1,50 64
Auxiliary (Small) (A) 0,90 71 0,65 71 0,90 50
Triple Crown (TC) 3,15 133 2,45 133 2,90 91
Semi-FishBurner (SP) 1,50 88 1,15 88 1,40 60
Supply pressures 25 mbar 25 mbar 30 mbar
At 15°C and 1013 mbar-dry gas
P.C.I. G20 35,9 MJ/M
3
P.C.I. G30 122,8 MJ/M
3
P.C.I. G25.1 30,9 MJ/M
3
R
S
S
A
R
S
S
A
RR
A
S
TC
TC
S
TC
PH 940 M/HA PH 941 M/HA PH 941 MSTV/HA PH 930.../HA
PH 940 MS/HA PH 941 MS/HA PH 941 MSTV GH/HA
TC
S
RR
A
RR
S
A
TC
SP
TC
S
RR
A
PH 941 MSTB/HA PH 960 MST/HA PH 940 MST/HA
PH 941 MSTB GH/HA PH 960 MST GH/HA
PH 960 MST R/HA
The hob can only be installed above built-in ovens with a cooling ventilation system.