20
GB
IE
Burners and nozzles specifications
This appliance conforms with the following European
Economic Community directives:
- 2006/95/EEC of 12/12/06 (Low Voltage) and subsequent
modifications;
- 2004/108/EEC of 15/12/04 (Electromagnetic Compatibility)
and subsequent modifications;
- 2009/142/EEC of 30/11/09 (Gas) and subsequent modifications;
- 93/68/EEC of 22/07/93 and subsequent modifications.
- 2002/96/EC and subsequent modifications.
* At 15°C and 1013 mbar-dry gas
Propane G31 H.s. = 50,37 MJ/kg
Butane G30 H.s. = 49,47 MJ/kg
Methane G20 H.s. = 37,78 MJ/m
3
Table 1 Liquid gas Natural gas
BURNER
Diameter
(mm)
Thermal power
kW (H.s.*)
By-pass
1/100
(mm)
Injector
1/100
(mm)
Flow *
g/h
Injector
1/100
(mm)
Flow*
l/h
Nomin. Reduc. G30 G31 G20
C.Rapid 100 3.00 0.7 40 86 218 214 116 286
B. Semi-rapid 75 1.65 0.4 30 64 120 118 96 157
A. Auxiliary 55 1.00 0.4 30 50 73 71 71 95
Supply pressure
Nominal
Minimum
Maximum
28-30
20
35
37
25
45
20
17
25
Comentarios a estos manuales